lis logo laboratory instrument specialist

Hanna Instruments pH Temperature Bench Meter HI15221-01

$699.99

Hanna Instruments pH Temperature Bench Meter HI5221-01 (Used)

Serial Number: 04370018101

Sold-as-is. Turns on but have performed any tests.

1 in stock

SKU: 13956_0FDB Category:

Additional information

Weight 8 lbs
Dimensions 21 × 13 × 9 in

Description

The Hanna Instruments pH Temperature Bench Meter HI5221 is an advanced research grade benchtop pH/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5221 features a universal BNC connection for use with the expansive line of pH and ORP electrodes that Hanna Instruments offers. This product is sold-as-is. It is preowned in great shape. Turns on but have not performed any tests on it.

Hanna Instruments pH Temperature Bench Meter General Specifications

  • Display: Color graphic LCD, 240 x 340 pixels

  • PC Connection: USB

  • Power Supply: 12 VDC adapter (included)

  • Operating Environment:

    • Temperature: 0 to 50°C (32 to 122°F; 273 to 323K)

    • Humidity: Max 95% RH, non-condensing

  • Dimensions: 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)

  • Weight: 1.2 kg (2.64 lbs)


pH Measurement

  • Range:

    • -2.0 to 20.0 pH

    • -2.00 to 20.00 pH

    • -2.000 to 20.000 pH

  • Resolution:

    • 0.1 pH, 0.01 pH, 0.001 pH

  • Accuracy:

    • ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD

  • Calibration:

    • Automatic

    • Up to 5-point calibration

    • 8 standard buffers: 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45

    • 5 custom buffers

  • Temperature Compensation:

    • Automatic or manual

    • Range: -20.0 to 120.0°C / -4.0 to 248.0°F / 253.15 to 393.15K


mV (ORP) Measurement

  • Range: ±2000 mV

  • Resolution: 0.1 mV

  • Accuracy: ±0.2 mV ±1 LSD

  • Relative mV Offset Range: ±2000 mV


Temperature Measurement

  • Range: -20.0 to 120.0°C / -4.0 to 248.0°F / 253.15 to 393.15K

  • Resolution: 0.1°C / 0.1°F / 0.1K

  • Accuracy: ±0.2°C / ±0.4°F / ±0.2K


Input Channels

  • 1 pH/ORP channel


Electrodes & Probes (Included)

  • pH Electrode: HI1131B glass body electrode with BNC connector, 1 m (3.3′) cable

  • Temperature Probe: HI7662-W stainless steel probe, 1 m (3.3′) cable


Data Logging

  • Storage Capacity:

    • Up to 100 lots

    • 50,000 records max per lot

    • Max 100,000 data points per channel

  • Logging Types:

    • Automatic

    • Manual

    • AutoHOLD

  • Interval Options: 14 selectable intervals between 1 second and 180 minutes


GLP Features

  • Calibration points

  • Calibration time stamp

  • Probe offset

  • Slope

  • Date and time

  • Buffers/standards used

Videos